Installation of Flooring at Child Development Center

Agency: DEPT OF DEFENSE
Level of Government: Federal
Category:
  • 72 - Household and Commercial Furnishings and Appliances
Opps ID: NBD00159311362967027
Posted Date: Feb 13, 2023
Due Date: Feb 24, 2023
Solicitation No: NAFVPCF001
Source: https://sam.gov/opp/03013049df...
Follow
Installation of Flooring at Child Development Center
Active
Contract Opportunity
Notice ID
NAFVPCF001
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AETC
Sub Command
JOINT BASE SAN ANTONIO
Office
FA9000 AF NAF PO
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information View Changes
  • Contract Opportunity Type: Sources Sought (Updated)
  • All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Updated Published Date: Feb 13, 2023 08:02 am CST
  • Original Published Date: Feb 10, 2023 09:45 am CST
  • Updated Response Date: Feb 24, 2023 12:00 pm CST
  • Original Response Date: Feb 24, 2023 12:00 pm CST
  • Inactive Policy: Manual
  • Updated Inactive Date: Feb 25, 2023
  • Original Inactive Date: Feb 25, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code:
  • NAICS Code:
    • 23833 - Flooring Contractors
  • Place of Performance:
    CO
    USA
Description View Changes

PLEASE DO NOT RESPOND TO THIS NOTICE UNLESS YOU CAN PROVIDE THE REQUIREMENTS LISTED BELOW.



Seeking Sources Sought for the contractor to provide all personnel, equipment, tools, materials, vehicles, supervision, certifications, storage for supplies, and other services necessary to deliver and install materials and equipment for a Child Development Center at an undisclosed Air Force Base.



Provide and install flooring per the requirements listed below.



Requirement

-Deliver and install new flooring in approximately 23 Child Activity Rooms, 7 adult restrooms, 1 Kitchen, 6 offices, and 3 meeting areas.

-Flooring system must meet ASTM 1292 5ft critical fall height.

-Must meet NAEYC, Caring for our Children, NPPS Standards, Consumer Product Safety Commission Standards, and CDC Draft Facility and flooring transition standards.

-Each classroom will meet the ADA Standards for Accessible Design with tapered/ramped edges to prevent tripping hazards.

-All work is to meet Child and Youth Fire and Safety operational requirements of the National Fire Protection Association, (NFPA 101, 2018 Edition) and applicable DoD criteria.



Shock Absorbing Flooring System:

. Meet indoor playground guidelines set by US Consumer Products Safety Commission (CPSC)

. Meet ASTM F 1292 and ASTM F 2373 at minimum 3 feet critical fall height with transition not to exceed 1/12 inch

. Meets ABA requirements

. Impact-absorbing mat/padding system

. Contains anti-microbial properties

. Solution dyed

. Integrated moisture barrier

. CRI Green Label

. Contains zero VOC’s

. Conventional cleaning process

. Integral wall base system

. Manufacturer’s representative shall be on site during application





The following criteria will be used for the hard surface flooring installed:

. The Mondo Sheet Rubber

. 7mm Cushioned Rubber Flooring (Activity Rooms)

. 55” wide sheet goods

. Meet ASTM D-2240 standards for Rubber Property (Durometer Hardness)

. Slip resistance standards shall meet or exceed ASTM D-2047 static coefficient of friction of 0.8

. Homogenous composition meeting ASTM F-1860 requirements

. 3 layer construction – rubber performance layer, Load Dispersion Layer, and comfort layer

. Minimum 10 year Limited Warranty

. Require minimal maintenance – no waxing or bleach

. Heat Welding Rod recommended for water tight installations

. Greenguard Indoor Air Quality Certified





. Resilient Wall Base

Minimum 10 cm (4”) high rubber base

- Cove base shall be installed at hard flooring locations where integral base is not installed

- Straight base shall be installed at all carpet areas





. Resilient Adhesives

- Water-based Acrylic adhesive

- Low VOCs

- No special ventilation requirements

- No Flash Point

- Contains no ingredients above the OSHA minimum reporting threshold listed by IARC, NTP, or OSHA



Contractor shall provide the following information in their response to this notice



-Capabilities Statement/briefing



-Contractor certifications for fall height requirements listed above




Attachments/Links
Contact Information View Changes
Contracting Office Address
  • CP 210 395 7821 2261 HUGHES AVE BLDG 171 SUITE 156
  • JBSA LACKLAND , TX 78236-9800
  • USA
Primary Point of Contact
Secondary Point of Contact


History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >